7ML19985DJ01 Milltronics BW100 - INSTRUCTION MANUAL Page 21
mmmmm
Start Up
To Access the PROGRAM Mode: 
Master Reset
Prior to programming, balancing and calibration, a master reset of the BW100 should be 
done. 
Refer to 
Parameter P999 
on
 
page 64. 
Load Cell Balancing
If you are operating a two load cell belt scale, it is recommended that the load cells be 
balanced electronically prior to initial programming and calibration, or after either or both 
load cells have been reinstalled or replaced. 
With the conveyor stopped and locked out, lift the belt off the weighing idlers. 
Note: Unbalanced load cells adversely affect the performance of your belt 
conveyor weighing system. 
1 2
e.g. rate display
last parameter from
previous PROGRAM session
e.g. P005
from the run mode
test weight bar
Load Cell
’B’
belt travel
typical dual load cell scale
Load Cell
’A’