EasyManua.ls Logo

Siemens Milltronics BW100 - Recalibration and Adjustments; Belt Speed Compensation

Siemens Milltronics BW100
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7ML19985DJ01 Milltronics BW100 - INSTRUCTION MANUAL Page 29
mmmmm
Start Up
Recalibration
Belt Speed Compensation
In order to achieve optimum accuracy in the rate computation, the belt speed displayed
must equal that of the actual belt speed. As the speeds are likely to differ, a belt speed
compensation should be performed.
Run the conveyor with the belt empty.
Stop the conveyor and measure a length of the belt; marking the forward end (start time)
and the back end (stop time). Use the belt scale as the stationary reference.
Run the belt and measure the time for the belt length to pass over the scale.
speed = belt length m or ft.
time s min.
Refer to
Maneuvering
on page 18 for parameter selection and value change.
If the BW100 constant speed input (TB1-5/6) is jumpered, the design speed (P014) is
automatically adjusted.
If a speed sensor is connected, the speed constant (P015) is automatically adjusted.
The display speed (used in the rate computation) now equals the actual speed.
Record the new value in Appendices/Program Record.
1 2
View the belt speed
run mode /speed display,
e.g. 0.750 m/s
%
with conveyor
running empty
jumps to P014 or P015
showing new value
enter calculated speed
e.g. 0.8 m/s
PROGRAM mode -
assumed speede.g.
0.75 ms