Parameters
P648 Totalizer Reset, Internal 
Resets the internal totalizers. 
Entry: 
0 = idle 
1 = reset totalizer 2 
2 = reset totalizers 1 and 2 
End of Totalization parameters. 
Communication (P751 - P761) 
These parameters are specific to the use of the communication parameters. Refer also to 
Communications
, page 47. 
P751 Baud Rate 
Sets the baud rate for the proprietary bi-polar current loop. This baud rate is not 
applicable to communication via Milltronics Comverter. 
Entry: 
300, 1200, 2400, 4800 or 9600 baud 
4800 baud is required for Dolphin communications over the bi-polar current loop. 
P760 Communication Mode 
Selects the communication mode. 
• bi-polar current loop:  interface with the host device (PLC or computer) 
• infrared link:  communication is made using the Milltronics ComVerter. 
• maintenance:  communication is made via the bi-polar current loop for 
RUN mode operations and infrared link for PROGRAM 
mode operations 
Entry: 
1 = bipolar current loop 
2 = infrared link 
3 = maintenance 
P761 Identification Number 
Sets the identification number for the unit. 
Enter the desired identification number, range 0 - 15.
End of communication parameters.