RUGGEDCOM RX1400
Installation Guide
Chapter 4
Technical Specifications
Power Supply Specifications 29
Technical Specifications
This chapter provides important technical specifications related to the device.
CONTENTS
• Section4.1, “Power Supply Specifications”
• Section4.2, “Failsafe Alarm Relay Specifications”
• Section4.3, “Fast Ethernet Port Specifications”
• Section4.4, “Serial Port Specifications”
• Section4.5, “Cellular Modem Specifications”
• Section4.6, “WLAN Specifications”
• Section4.7, “Operating Environment”
• Section4.8, “Mechanical Specifications”
Section4.1
Power Supply Specifications
The RUGGEDCOM RX1400 includes one of the following internal power supplies:
Power Supply Type Input Range Internal Fuse Rating
a
Maximum Power
Consumption
b
88-264 VAC
HI
98-300 VDC
±48V VDC ±36-72 VDC
3.15 A(T)
12-24 VDC 9-36 VDC
±12-24 VDC ±36 VDC
6.3 A(T)
< 15 W
a
(T) denotes time-delay fuse.
b
Power consumption varies based on the device configuration.
Section4.2
Failsafe Alarm Relay Specifications
Parameter Value (Resistive Load)
Max Switching Voltage 240 VAC