General industry standards
The SIMATIC CN 4100 communication system is designed to meet or exceed most general
industry standards. These are in particular:
Power input on shielded and unshielded signal lines:
IEC 61000-4-6 (Ed. 4.0 2013-10 + corr. 1:2015); EN 61000-4-6 (2014-02); DIN EN 61000-4-6
(2014-08)
Immunity testing, high frequency electromagnetic 󹪝eld:
IEC 61000-4-3 (2008-04+A2:2010-03); EN 61000-4-3
(2006-05+A1:2008-02+A2:2010-07); DIN EN 61000-4-3 (2011-04).
Measurement of conducted emissions on telecommunication lines: 150 kHz - 30 MHz:
EN 55016-2-1:2009-03+A1:2011-04+A2:2013-05 (CISPR 16-2-1).
Burst – Immunity of shielded signal lines:
IEC 61000-4-4 (2012-04); EN 61000-4-4 (2012-11); DIN EN 61000-4-4 (2013-04).
ESD - Electrostatic discharge:
IEC 61000-4-2 (2008-12 ed. 2); EN 61000-4-2 (2009-03); DIN EN 61000-4-2 (2009-12)
Interference emission measurement:
30 MHz - 1 GHz according to EN 55016-2-3:2010 (CISPR 16-2-3)
1-6 GHz according to EN 55016-2-3:2010 (CISPR 16-2-3)
10.1.3 UKCA marking
Importer UK:
Siemens plc
Manchester M20 2UR
10.1.4 cULus approval
Introduction
The cULus approval applies to:
Rack
CPU modules
De󹪝nition
R
Technical speci󹪝cations
10.1 Standards and approvals
CN 4100 Communication System
Equipment Manual, 10/2021, A5E50871363-AA 61

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC CN 4100 and is the answer not in the manual?

Siemens SIMATIC CN 4100 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC CN 4100
CategoryConference System
LanguageEnglish

Related product manuals