Introduction to the CPU 410
2.7 I/O configuration variants of the fault-tolerant system
CPU 410 Process Automation/CPU 410 SMART
System Manual, 05/2017, A5E31622160-AC
31
2.7
I/O configuration variants of the fault-tolerant system
I/O configuration variants
The following configuration variants are available for the input/output modules:
In stand-alone operation: one-sided configuration.
In the one-sided configuration, there is a single set of the input/output modules (single-
channel) that are addressed by the CPU.
In redundant operation: Single-channel switched configuration with enhanced availability.
In the single-channel switched distributed configuration, there is a single set of the I/O
modules, but they can be addressed by both subsystems.
In redundant operation: Dual-channel configuration with maximum availability.
In dual-channel switched configuration, there are two of each of the input/output modules
and the modules can be addressed by both subsystems.
2.8
Configuration tools (STEP 7 HW Config, SIMATIC PCS 7)
Like S7-400, CPU 410-5H Process Automation is configured with STEP 7 HW Config.
You can find information on limitations for configuring CPUs and the fault-tolerant system in
the STEP 7 HW Config online help.
Optional software
You can use all optional packages available in SIMATIC PCS 7.
2.9
The SIMATIC PCS 7 project
STEP 7
STEP 7 is the core component for configuring the SIMATIC PCS 7 process control system
with the engineering system.
STEP 7 supports the various tasks involved in creating a project with the following project
views:
Component view (HW Config)
Process object view
Technological perspective
The hardware that you need in a SIMATIC project, such as automation systems,
communication components, and process I/O, is stored in an electronic catalog. You
configure this hardware and assign the hardware parameters with HW Config.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC CPU 410 and is the answer not in the manual?

Siemens SIMATIC CPU 410 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC CPU 410
CategoryControl Unit
LanguageEnglish

Related product manuals