Technical specifications
7.1 Specifications
ET 200SP F-TM Count 1x1Vpp sin/cos HF (6ES7136-6CB00-0CA0)
Equipment Manual, V1.0, 01/2021, A5E47073911-AA
83
Counting frequency (counter) max.
800 kHz; with quadruple evaluation
Safety monitoring functions
Safe Operating Stop (SOS)
Safely-Limited Speed (SLS)
Counter response parameterizable
Counting range, parameterizable
Frequency measurement, min.
Frequency measurement, max.
Cycle duration measurement, min.
Cycle duration measurement, max.
Velocity measurement, min.
Velocity measurement, max.
2147483; +/- (user defined units)
Up to 100 ppm; depending on measuring interval
and signal evaluation. At low frequency external
noise may have an effect on accuracy (reference
Cycle duration measurement
Up to 100 ppm; depending on measuring interval
and signal evaluation. At low frequency external
noise may have an effect on accuracy (reference
Up to 100 ppm; depending on measuring interval
and signal evaluation. At low frequency external
noise may have an effect on accuracy (reference
Potential separation channels
No; Only one channel is available
between the channels and backplane bus
Between the channels and load voltage L+
between the channels and the power supply of
the electronics
Degree and class of protection
Standards, approvals, certificates
Suitable for safety functions