Analog input module AI Energy Meter 480VAC ST (6ES7134-6PA20-0BD0)
Manual, 12/2015, A5E36061895-AA
5
Table of contents
Preface ................................................................................................................................................... 4
1 Documentation guide .............................................................................................................................. 8
2 Product overview .................................................................................................................................. 11
2.1 Area of application .................................................................................................................. 11
2.2 Properties of the AI Energy Meter 480VAC ST ...................................................................... 13
3 Wiring ................................................................................................................................................... 15
3.1 Terminal and block diagram ................................................................................................... 15
3.2 Connection examples ............................................................................................................. 18
3.3 Current transformer selection data ......................................................................................... 21
4 Configuration / address space ............................................................................................................... 25
4.1 Configuring .............................................................................................................................. 25
4.2 Selecting the module versions ................................................................................................ 26
4.2.1 Module versions at configuration with STEP 7 ....................................................................... 27
4.2.2 Module versions at configuration with GSD file ...................................................................... 28
4.2.3 Changing over the user data variant during operation ........................................................... 29
4.2.4 Recommendations for selecting the module version .............................................................. 30
4.3 Applicable modules ................................................................................................................. 31
5 Quick start ............................................................................................................................................ 33
6 Reading and processing measured values ............................................................................................ 35
6.1 Basics for reading measured values ....................................................................................... 35
6.2 Quality information .................................................................................................................. 37
6.3 Reading measured values from user data cyclically .............................................................. 40
6.4 Read measured value from a measured value data record ................................................... 42
7 Energy counters .................................................................................................................................... 43
7.1 How the energy meter works .................................................................................................. 43
7.2 Configuring counters ............................................................................................................... 46
7.3 Evaluate energy counter and overflow counter ...................................................................... 47
7.4 Resetting energy counters and overflow counters ................................................................. 48
7.4.1 Reset energy counters via user data ...................................................................................... 48
7.4.2 Resetting energy counters and overflow counters via data record DS 143 ........................... 50
7.4.3 Example for energy counters and overflow counters via data record DS 143 ....................... 52
7.5 Data record for energy counter (DS 143) ............................................................................... 55
7.5.1 Structure for energy counters (DS 143) .................................................................................. 55
7.5.2 Structure of the control and feedback interface for DS 143.................................................... 60

Table of Contents

Other manuals for Siemens simatic et200sp

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens simatic et200sp and is the answer not in the manual?

Siemens simatic et200sp Specifications

General IconGeneral
CategoryI/O Systems
Power Supply24 V DC
Protection RatingIP20
Number of ModulesUp to 64 modules
MountingDIN Rail
Communication ProtocolsPROFINET, PROFIBUS
Storage Temperature-40 °C to +70 °C
Digital InputsYes (depending on module)
Digital OutputsYes (depending on module)
Analog InputsYes (depending on module)
Analog OutputsYes (depending on module)
ModularityModular
Relative Humidity5 to 95% (non-condensing)
WeightVaries by configuration
System TypeDistributed I/O