Setting parameters for blocks
3.4 Programming Ident blocks
Ident profile and Ident blocks, standard function for Ident systems
66 Function Manual, 10/2018, C79000-G8976-C387-04
Table 3- 47 ATTRIBUTE "0x80" ("IID_TAG_STATUS_80_MOBY_U" data type)
Name
Type
Comment
UID
ARRAY [1..4]
of BYTE
Unique indentifier (MDS-Number)
MDS type
BYTE
Type of MDS
sum subframe access 1
BYTE
Sum of subframe access Byte 1
sum subframe access 2
BYTE
Sum of subframe access Byte 2
sum subframe access 3
BYTE
Sum of subframe access Byte 3
sum subframe access 4
BYTE
Sum of subframe access Byte 4
sum searchmode access 1
BYTE
Sum of search mode access Byte 1
sum searchmode access 2
BYTE
Sum of search mode access Byte 2
ST date Week
BYTE
Date of last sleep-time change (week of year)
ST date Year
BYTE
Date of last sleep-time change (year)
battery left 1
BYTE
Battery power left (percent) Byte 1
battery left 2
BYTE
Battery power left (percent) Byte 2
ST
BYTE
Actual sleep-time on MDS
Table 3- 48 ATTRIBUTE "0x82" ("IID_TAG_STATUS_82_RF300" data type)
Name
Type
Comment
reserved
BYTE
status info
BYTE
MDS status mode
UID
ARRAY [1..8]
of BYTE
LFD
BYTE
Magnetic flux density: correlation between limit-value
FZP
BYTE
Error counter passive: distortion without communication
FZA
BYTE
Error counter active: distortion during communication
ANWZ
BYTE
Presence counter: measure value for presence time
reserved1
ARRAY [1..3]
of BYTE
Table 3- 49 ATTRIBUTE "0x83" ("IID_TAG_STATUS_83_ISO" data type)
Name
Type
Comment
reserved
BYTE
status info
BYTE
MDS status mode
UID
ARRAY [1..8]
of BYTE
MDS Type
BYTE
Type of MDS
IC version
BYTE
Chip version
size HB
BYTE
Size of Memory (high Byte)
size LB
BYTE
Size of memory (low Byte)
lock state
BYTE
Write protection status EEPROM
block size
BYTE
Size of a block in addressable memory
number of block
BYTE
Number of blocks in addressable memory
Table 3- 50 ATTRIBUTE "0x84" ("IID_TAG_STATUS_84_RF600" data type)
Name
Type
Comment
reserved
BYTE
status info
BYTE
MDS status mode
UID
ARRAY [1..8]
of BYTE
antenna
BYTE
Antenna which has observed the MDS
RSSI
BYTE
RSSI value

Table of Contents