Setting parameters for blocks
3.4 Programming Ident blocks
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04
67
Name
Type
Comment
last observed hour
BYTE
Last observed time hour
last observed min
BYTE
Last observed time minute
last observed sec
BYTE
Last observed time seconds
last observed channel
BYTE
Last observed time channel
EPC length
BYTE
EPC-Length
reserved1
BYTE
1)
The internal time stamp of the internal reader clock that relates to this event is output. The internal reader clock is not
synchronized with UTC.
Table 3- 51 ATTRIBUTE "0x85" ("IID_TAG_STATUS_85_RF600" data type)
Name
Type
Comment
status info
BYTE
MDS status mode
antenna
BYTE
Antenna which has observed the MDS
channel
BYTE
Channel
UID
ARRAY [1..8]
of BYTE
DT_glimpsed_1
BYTE
Time elasped between acknowledgement and first read in
[ms]1 Highbyte
DT_glimpsed_2
BYTE
Time elasped between acknowledgement and first read in
[ms]2
DT_glimpsed_3
BYTE
Time elasped between acknowledgement and first read in
[ms]3
DT_glimpsed_4
BYTE
Time elasped between acknowledgement and first read in
[ms]4 Low-Byte
reserved1
BYTE
reserved2
BYTE
reserved3
BYTE
reserved4
BYTE
last observed hour
BYTE
Last observed time hour
last_observed_min
BYTE
Last observed time minutes
1)
last_observed_sec
BYTE
Last observed time seconds
1)
last observed EPC length
BYTE
Last observed time EPC length
EPC_ID_Byte
ARRAY [1..62]
of BYTE
EPC-ID
reads HB
BYTE
Number of Reads of MDS in Inventory (1 - 65535)
reads LB
BYTE
Number of Reads of MDS in Inventory (1 - 65535)
RSSI
BYTE
Current RSSI value of MDS
2)
mean RSSI
BYTE
Mean RSSI value of MDS
max RSSI
BYTE
Max RSSI value of MDS
min RSSI
BYTE
Min RSSI value of MDS
min POWER
BYTE
Min Power value of MDS
current_POWER
BYTE
Current Power value of MDS
3)
reserved5
ARRAY[1..137]
of BYTE
1)
The internal time stamp of the reader that relates to this event is output. The internal reader time stamp is not synchro-
nized with UTC.
2)
The value "Reads" indicates the total transponder recognitions (inventories) regardless of the set smoothing parame-
ters. In this way, in extreme situations, the "Reads" counter can reach extremely high values without the transponder
ever reaching the "Observed" status.
3)
The "current_Power" value is specified as transmit power in 0.25 dBm steps (ERP/EIRP). A "current_Power" value of
"72" (0x48) therefore corresponds to 18 dBm (ERP/EIRP).