Setting parameters for blocks
3.5 Programming the Ident profile
Ident profile and Ident blocks, standard function for Ident systems
86 Function Manual, 10/2018, C79000-G8976-C387-04
Table 3- 63 Explanation of the structure of the data attachment for the "FORMAT" command
Byte
Description
Bytes 1...8 Reserved for security code (must be assigned "0", since SIMATIC RFID has had
no code previously)
Byte 9 Length of the following data, here 6
Byte 10
Permanently set to "0x03"
Byte 11 Permanently set to "0x00"
Byte 12 "INIT" value: The data area of the transponder is written with this value (hex for-
mat).
Byte 13
Permanently set to "0x00"
Byte 14
Memory size of the transponder (end address + 1; high byte, hex format)
Byte 15
Memory size of the transponder (end address + 1; low byte, hex format)
Table 3- 64 Memory sizes of the transponders
Transponder type
Memory size
INIT duration
2 KB
32 KB
MOBY U
MOBY U
RAM *
)
RAM *
)
08 00
80 00
approx. 1 s
approx. 1.5 s
44 bytes
112 bytes
256 bytes
992 bytes
2000 bytes
MOBY D
MOBY D
MOBY D
MOBY D
MOBY D
I-Code 1
ISO I-Code SLI
ISO Tag-it HF-I
ISO my-d
FRAM
00 2C
00 70
01 00
03 E0
07 D0
approx. 0.4 s
approx. 0.5 s
approx. 1 s
approx. 3 s
approx. 3 s
20 bytes
8 KB
32 KB
64 KB
RF300
RF300
RF300
RF300
EEPROM
FRAM *)
FRAM *)
FRAM *)
00 14
20 00
80 00
FF 00
approx. 0.2 s
0.9 s
3.6 s
7.2 s
*
)
The OTP memory is not initialized with this command.
Table 3- 65 PUT (not with RF61xR/RF68xR)
Parameter
Value / description
CMD
0x65
OFFSETBUFFER
Offset in the "TXREF" send buffer
LEN_DATA
Length of the parameter data to be sent
TXREF
Parameter data to be written