3.5 Programming the Ident profile
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04
93
Byte
Value
RFID system
Meaning
RF600
RFID mode setting
Bit Description
7 ... 5 Presence check and transponder control:
0x00 = Operation without presence check
0x01 = Operation with presence check
Antenna is permanently switched on.
4 To be assigned the value "0x00".
3 ... 0 RFID mode:
0x04 = ISTM mode
0x05 = Single tag mode
0x06 = With single tag mode (UID = 0x00), 4 bytes UID of the 8 byte
handle ID or
With multitag mode, 4-byte UID as handle ID for accessing the tran-
sponder with EPC-ID of any length
0x07 = With single tag mode (UID = 0x00), 8 bytes UID or
With multitag mode, 8-byte UID of bytes 5-12 of 12-byte long EPC-ID
Note: Note that after a parameter change the CM must be restarted.
Byte 11
option_1 RF200,
RF300,
MOBY D,
MOBY U
This byte is bit-coded. As default, it has the value "B#16#0". With this byte, special
controllers can be implemented on the CM/reader.
Bit
Description
1 0x01 = Flashing of the "ERR" LED is reset by a "WRITE-CONFIG".
With RF200/RF300, this resets the flashing of the "ERR" LED on the
communications module and on the reader.
RF600
This byte is bit-coded. As default, it has the value "B#16#0".
Bit
Description
1 0x01 = Flashing of the "ERR" LED of the communications module is
reset by a "WRITE-CONFIG".
2
0x00 = OFF
0x01 = ON