Setting parameters for blocks
3.5 Programming the Ident profile
Ident profile and Ident blocks, standard function for Ident systems
92 Function Manual, 10/2018, C79000-G8976-C387-04
Byte
Value
RFID system
Meaning
...
...
0xC8 1400 ms standby time
Byte 10
param RF200,
RF300,
MOBY D,
MOBY U
Setting for the RFID mode and presence check
Bit Description
7 ... 5 Presence check and transponder control:
0x00 = Operation without presence check
0x01 = Operation with presence check
Antenna is permanently switched on.
0x04 = Operation without presence check
Antenna is switched off. The antenna is only switched on when one
of the following commands is sent: Read, Write, Init, Tag-Status
4
To be assigned the value "0x00".
3 ... 0 RFID mode:
0x05 = Without multitag mode with communications module ASM
475, ASM 456, RF170C, RF180C
0x06 = With multitag mode with communications module ASM 475,
ASM 456, RF170C, RF180C
Only with MOBY U
Value of bit 3 ... 0
Value
of bit 3
... 0
Operating
mode
Description
0x00 Reserved reserved for the setting with the switch or GSD pa-
rameter assignment
0x01 MOBY I If RF300 readers of the 2nd generation are to be oper-
ated in MOBY I mode, the value = 0x01 must be set.
Short "INIT" (only the "param" and "option_1" parame-
ters are transferred to the reader).
0x05 MOBY U/D,
RF200, RF300
- without multi-
tag mode
ASM 475, ASM 456, RF170C, RF180C
0x06 MOBY U - with
mulititag mode
(FB 55)
Parameter setting with Multitag > 1 and more than
one transponder in the antenna field: the UID pa-
rameter must be supplied with the transponder ID.
Parameter setting with Multitag = 1 and only one
transponder in the antenna field: the UID parameter
can be supplied with the correct transponder ID or
zero.
ASM 475, ASM 456, RF170C, RF180C
0x07 MOBY D,
RF300 - with
mulititag mode
(FB 55)
ASM 475, ASM 456, RF170C, RF180C
Note: Note that after a parameter change the CM must be restarted.