Configuring with Web Based Management
5.6 "Interfaces" menu
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
180 Configuration Manual, 11/2014, C79000-G8976-C350-03
Description
The table has the following columns:
Radio
Shows the available WLAN interfaces in this column.
A-MPDU
Enables or disables the sending of A-MPDU data packets. If this check box is disabled,
only A-MPDU data packets are received.
A-MPDU Limit [Frames]
Specify the number of individual data packets grouped together in one AMPDU data
packet.
Range of values: 2 - 64 frames
A-MPDU Limit [Bytes]
Specify the maximum size of the AMPDU data packet. Range of values: 1024 - 65535
bytes
Guard Interval [ns](Only in access point mode)
Select the send pause that must be kept to between two transmitted OFDM symbols.
The following settings are possible. The selection depends on the selected transmission
standard.
400 (short): The send pause is 400 ns
800 (long): The send pause is 800 ns.
Procedure
Configure 802.11n settings on the access point
1. Enable the "A-MPDU" option.
2. Enter the required values in the "A-MPDU Limit [Frames]" and "A-MPDU Limit [Bytes]"
input boxes.
3. Select the required value from the "Guard Interval [ns]" drop-down list.
4. Click the "Set Values" button.
Configure 802.11n settings on the client
1. Enable the "A-MPDU" option.
2. Enter the required values in the "A-MPDU Limit [Frames]" and "A-MPDU Limit [Bytes]"
input boxes.
3. Click the "Set Values" button.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W721-1 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W721-1 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W721-1
CategoryControl Unit
LanguageEnglish

Related product manuals