Configuring with Web Based Management
6.4 "Information" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
120 Configuration Manual, 08/2018, C79000-G8976-C267-13
The content area shows a graphic of the device. The graphic always shows the device
whose WBM you have called up.
The following is displayed below the picture of the device:
●
Shows the PROFINET device name.
●
Shows whether EtherNet/IP or PROFINET is enabled.
●
Shows the name of the device.
●
Shows the type designation of the device.
●
Shows the PROFINET application relation status.
– Online
There is a connection to a PROFINET controller. The PROFINET controller has
downloaded its configuration data to the device. The device can send status data to
the PROFINET controller.
In this status, the parameters set by the PROFINET controller cannot be configured on
the device.
– Offline
There is no connection to a PROFINET controller.
●
Power Line 1 / Power Line 2 / Power over Ethernet
Status of the power supplies 1 and 2 or power over Ethernet. The power line 2 and Power
over Ethernet are only displayed if they are supported by the hardware. You will find
further information on this in the operating instructions.
●
Shows the status of the configuration data on the PLUG, refer to the section "System >
PLUG > Configuration".
●
Shows the fault status of the device.
●
Shows whether or not the function is enabled.