Programming via SIMATIC controller
8.6 Programming the Ident profile
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
143
Table 8- 25 INVENTORY
0x69 Offset in the
"RXREF" receive
buffer
Identifier of the sta-
tus modes / possible
entries:
• 0x80 ≙ inventory
with brief tran-
sponder infor-
mation
• 0x81 ≙ inventory
with a lot of tran-
sponder infor-
mation
• 0x86 ≙ Presence
mode on
• 0x87 ≙ Presence
mode off
Only for 0x80 and
0x81:
Duration
Period of time or
number of invento-
ries or number of
"Observed" events
Example:
• 0x00 ≙ no inven-
tory
• 0x01 ≙ one in-
ventory
Only for 0x80 and
0x81:
Unit for "DURATION"
• 0x00 ≙ time [ms]
• 0x01 ≙ invento-
ries
• 0x02 ≙ number of
"Observed"
events
Only for 0x80 and
0x81:
Data received
You will find the data
structure of the
modes in the section
"Inventory
(Page 125)".
Table 8- 26 WRITE-ID
0x67 Offset in the
"TXREF" send
buffer
EPC ID
0x00 ≙ unspeci-
fied single tag
access
Length of the
EPC-ID (2-62
bytes)
0x00 ≙ unspeci-
fied single tag
Length of the new
EPC-ID
Password
0x00 ≙ no
password
New EPC-ID
Table 8- 27 KILL-TAG
0x6A EPC ID
0x00 ≙ unspecified single
tag access
Length of the EPC-ID (2-
62 bytes)
0x00 ≙ unspecified single
Password
must be ≠0x00
--