Programming via XML interface
10.3 XML commands
SIMATIC RF650R/RF680R/RF685R
230 Configuration Manual, 03/2018, C79000-G8976-C386-06
information on parameters in the section "The "Settings - Read points" menu item
(Page 54)".
Note
Filter mechanisms influence the results
Defined filter mechanisms influence the results (refer to the section "
The "Settings - Filters"
menu item
(Page 68)"). Then in the reply frame, only the transponders that were not filtered
out appear.
Note
Delay of the reply frames
A reply frame of the reader can be delayed additionally by
the set duration of the command.
Command
<frame>
<cmd>
<id> value_id </id>
<getObservedTagIDs>
<sourceName> value_sourceName </sourceName>
<duration> value_duration </duration> // opt
<unit> value_unit </unit> // opt
</getObservedTagIDs>
</cmd>
</frame>
// opt → Optional: Line can be omitted.
Reply
<frame>
<reply>
<id> value_id </id>
<resultCode> 0 </resultCode>
<getObservedTagIDs>
<returnValue>
<tag>
<tagID> value_tagID </tagID>
<tagPC> value_tagPC </tagPC> // opt
<utcTime> value_utcTime </utcTime> // opt
<antennaName> value_antennaName </antennaName> // opt
<rSSI> value_rSSI </rSSI> // opt
<channel> value_channel </channel> // opt
<power> value_power </power> // opt
<polarization> value_polarization </polarization> // opt