Programming via XML interface
10.3 XML commands
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
231
<inventoried> value_inventoried </inventoried> // opt
<filterDataAvailable> value_filterDataAvailable
</filterDataAvailable> // opt
// opt → Optional: Line can be omitted.
The error codes for negative replies ("resultCode" ≠0) are described in the section "Negative
XML replies (Page 263)".
value_id Decimal value
0...4294967295 Unique command identifier
value_
sourceName
Text -- Read point name
The name is specified using the WBM
(refer to the section "The "Settings -
Read points" menu item (Page 54
)").
In the standard configuration, there is
only one read point with the name
value_duration Decimal value
0...9
0...65535 Optional
Period of time for which the selected
read point should read transponders.
If a value "0" is set or the parameter is
empty, the transponders are returned
immediately to the "Observed" status
without a time or a read cycle being
executed.
This behavior is particularly interesting
when the data source is controlled by
other points (e.g. inputs).
value_unit Fixed values Time
Count
Optional
Specifies the unit for the duration.
• Time = time in milliseconds
• Count = number of inventories
If no value is set, the duration is speci-