Appendix
A.1 Planning and installation of UHF read points
SIMATIC RF650R/RF680R/RF685R
314 Configuration Manual, 03/2018, C79000-G8976-C386-06
Note that the RSSI value depends on the following components:
transponder used,
antenna used,
Polarization,
reflecting and absorbent materials in the vicinity of the antenna.
Radiated power
Using the "Settings - Read points" menu item of the WBM, you can set the radiated power.
Select the radiated power so that the required transponders can be identified reliably but
without overreach. In this case, the following applies: "as much as necessary, as little as
possible".
In the "Settings - Activation power" menu item, you can find the optimum radiated power for
reliable transponder access.