Configuring with the WBM
7.3 The menu items of the WBM
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
69
The "Filters" area contains a list of all created filters. To edit a filter profile, select the
required filter in the list. The selected filter is highlighted in color. Click the "Insert" button to
create a new filter. Click the "Delete" button to delete an existing selected filter.
In the "Filter properties" area, you can adapt the properties of the individual filters. To allow
filter functions to take effect, the information defined in the filter must be read out from the
transponders and compared with the filter criteria.
Table 7- 12 Description of the filter properties
Input box for assigning a logical name/ descriptive title to the filter.
Bank Drop-down list for selecting the memory bank in which the memory area
Start address
Address starting at which the filter will be checked.
Value range 0 ... 65535 bytes
Length Number of bytes to be checked starting at the start address. The value
specified here affects the length of the input boxes "Mask" and "Value".
Criterion Specifies which value the checked positions must contain HEX repre-
ASCII Hiding/unhiding the ASCII view.
When the ASCII view is active, the values of the criterion are shown
additionally in ASCII notation. You can edit the values both in the HEX
format or in the ASCII format.
You can choose between the two input modes "Overwrite" and "Insert".
Mask Showing/hiding the mask.
Specifies which positions of the criterion should be checked.
Example: 00FF → Bits 0 ... 8 of the criterion will be checked.
Initialize data Show/hide the view for initializing the data.
Using the initialization function, you can preset the boxes of the criterion