Configuring with the WBM
7.3 The menu items of the WBM
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
87
Figure 7-17 The "Settings - Activation power" menu item
Procedure for determining the activation power
Note
Do not optimize the activation power during operation
We
recommend that you do not optimize (
) the activation power during operation since this
can disturb operation.
Select
the required read point and antenna, enter the required measuring range values
and start the measurement.
Select a transponder from the list.
Transfer the activation power to the "Radiated power" input box of the "Settings
- Read
points" menu item.