General information
2.7 Technical data
SINAMICS V90, SIMOTICS S-1FL6
62 Operating Instructions, 04/2019, A5E36037884-007
Parameter
Description
Torque limit Set through a parameter or the analog input command (0 V DC to +10 V DC/max.
torque)
Torque control mode
Analog torque command input
-10 V DC to +10 V DC/max. torque (input impedance 10 kΩ to 12 kΩ)
Speed limit Set through a parameter or the analog input command (0 V DC to +10 V DC/max.
rated speed)
Environmental conditions
Surrounding air
temperature
Operation
0 °C to 45 °C: without power derating
45 °C to 55 °C: with power derating
Storage
-40 °C to +70 °C
Ambient humidity
Operation
< 90% (non-condensing)
Storage
90% (non-condensing)
Operating environment Indoors (without direct sunlight), free from corrosive gas, combustible gas, oil gas, or
dust
Altitude ≤ 1000 m (without power derating)
Degree of protection
IP 20
Degree of pollution
Class 2
Vibration
Operation
Shock Operational area II
Peak acceleration: 5 g, 30 ms and 15 g, 11 ms
Quantity of shocks: 3 per direction × 6 directions
Duration of shock: 1 s
Vibration Operational area II
10 Hz to 58 Hz: 0.075 mm deflection
58 Hz to 200 Hz: 1 g vibration