General information
2.7 Technical data
SINAMICS V90, SIMOTICS S-1FL6
66 Operating Instructions, 04/2019, A5E36037884-007
Operation
Shock Operational area II
Peak acceleration: 5 g, 30 ms and 15 g, 11 ms
Quantity of shocks: 3 per direction × 6 directions
Vibration Operational area II
10 Hz to 58 Hz: 0.075 mm deflection
58 Hz to 200 Hz: 1 g vibration
Product packag-
ing
Vibration 2 Hz to 9 Hz: 3.5 mm deflection
9 Hz to 200 Hz: 1 g vibration
Quantity of cycles: 10 per axis
Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be
provided in accordance with the National Electrical Code and any additional local codes.
The V90 200 V servo drive has an overvoltage threshold of 410 V DC and an undervoltage threshold of 150 V DC; the
V90 400 V servo drive has an overvoltage threshold of 820 V DC and an undervoltage threshold of 320 V DC.
SINAMICS V90 does not support motor overtemperature protection. Motor overtemperature is calculated by I
2
t and
protected by the output current from the drive.
Max. supported motor power
0.4 0.75 1.0 1.75 2.5 3.5 5.0 7.0
Outline dimensions (W x H x
60 x 180
80 x 180 x 200 100 x 180 x 220 140 x 260 x 240
1)
Regenerative resistor (W)
3-phase 380 VAC to 480 VAC, 50/60 Hz
Permissible voltage fluctua-
-15% to +10%
Permissible frequency fluc-
-10% to +10%