General information
2.7 Technical data
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
67
Order No. 6SL3210-5FE...
10-4UA0
10- 8UA0
11-0UA0
11-5UA0
12- 0UA0
13-5UA0
15-0UA0
17-0UA0
Frame size
FSAA
FSA
FSA
FSB
FSB
FSC
FSC
FSC
Permissible supply configu-
ration
TN, TT, IT
Short-circuit current (SCCR) Maximum permissiIble short-circuit current: 65 kA rms
Minimum required short-circuit current: 5 kA rms
Rated input current (A) 1.5 2.6 3.8 6.6 9.8 13.8 15.8 16.5
Power supply capacity (kVA)
1.7
3.0
4.3
7.6
11.1
15.7
18.0
18.9
Inrush current (A)
8.0
8.0
8.0
4.0
4.0
2.5
2.5
2.5
24 VDC power supply
Voltage (V)
24 (-15% to +20%)
2)
Maximum current (A) When using a motor without a brake: 1.6 A
When using a motor with a brake: 1.6 A + motor holding brake rated current (See Section
Technical data - servo motors (Page 73)".)
Ripple caused by the rectifier
≤ 5%
Safety insulation class
PELV
1)
The values here are calculated at rated load.
2)
When SINAMICS V90 works with a motor with a brake, the voltage tolerance of 24 VDC power supply must be -10% to
+10% to meet the voltage requirement of the brake.

Table of Contents

Other manuals for Siemens SIMOTICS S-1FL6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS S-1FL6 and is the answer not in the manual?

Siemens SIMOTICS S-1FL6 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS S-1FL6
CategoryServo Drives
LanguageEnglish

Related product manuals