Commissioning (software)
7
7.1 Overview of commissioning
Requirements
The following requirements must be fulfilled in order to commission the SIMOTION D:
The system has been connected and wired.
The SIMOTION D has been switched on and powered up (STOP mode).
SIMOTION SCOUT (with integrated STARTER) has been installed and powered up on the
PG/PC.
The communication and networks have been configured.
You have created a project and inserted a SIMOTION D in the project.
Note
The article numbers of the SINAMICS S120 components must be available.
You need these order numbers when setting up a SIMOTION project to verify that the
components
selected from the hardware catalog in the HW Config application correspond
to the ones used in the system.
7.1.1 Symbolic assignment / adaptation
Symbolic assignment
As of V4.2, SIMOTION supports the symbolic assignment on SINAMICS drive objects (DOs)
during the configuration of technology objects (TO) and I/Os.
This
simplifies the configuration of the technological relationships including the communication
between controller and drive.
With the symbolic assignment:
Only suitable assignment partners are offered in an assignment dialog box.
Communication between axis and drive is set up automatically by the engineering system
and the required PROFIdrive axis telegrams as well as the used addresses set up.
Telegrams are extended and interconnections created automatically in the drive depending
on the selected TO technology (e.g. SINAMICS Safety Integrated).
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B 169

Table of Contents

Other manuals for Siemens SIMOTION CX32-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION CX32-2 and is the answer not in the manual?

Siemens SIMOTION CX32-2 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION CX32-2
CategoryControl Unit
LanguageEnglish

Related product manuals