Commissioning   
4.2 Table of the settings 
  Connecting SIMOVERT MASTERDRIVES MC to the Technology-CPU 
14  Product Information, 03/2008, A5E00272072-05 
4.2  Table of the settings 
Settings for commissioning 
You will require this data for the following commissioning steps. As preparation, you can 
define the values using this table. 
 
DP cycle  ________ ms  
❑ Incremental encoder Specify Encoder 
❑ Absolute encoder 
❑ Reference cam + encoder zero mark 
❑ Only encoder zero mark 
❑ Only reference cam 
❑ 1. Zero position to the right of the 
reference cam 
Referencing mode  
❑ 1. Zero position to the left of the 
reference cam 
"Measuring" function  ❑ 
Encoder type (Order No.)  1Fxxxxx- _ xxxx-x _ xx 
Rated motor speed/max. speed, axis  ______ 1/min 
Master application cycle/position controller 
clock cycle 
______ 
Telegram type (refer to the decision table)  ______ 
PROFIBUS address  ______