Siemens SINAMICS G120 - Page 196

Siemens SINAMICS G120
450 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6SHHG
6',DFWLYH
672DFWLYH
212))
'HVHOHFW6',
6WDQGVWLOO
6SHHG
6',DFWLYH
672DFWLYH
212))
'HVHOHFW6',
6WDQGVWLOO
W
W
W
6',
W
W
W
6',
Figure 5-34 Feedback signal SDI when the motor is switched offLeft: SDI becomes inactive. Right: SDI
remains active
Switching off the motor when SDI is active (Page 283)
Parameter Description
p1051 Speed limit RFG positive direction of rotation (Factory setting depends on the Control
Unit)
p1052 Speed limit RFG negative direction of rotation (Factory setting depends on the Control
Unit)
p1135 OFF3 ramp-down time
p9501.00 1 signal: Enable extended functions.
0 signal: Disable extended functions.
p9501.17 1 signal: Enable SDI
0 signal: Inhibit SDI
p9509.08 1 signal: SDI becomes inactive when the motor is switched off
0 signal: SDI remains active when the motor is switched off
p9564 Tolerance (Factory setting: 12 degrees)
p9565 Delay time (Factory setting: 100 ms)
p9566 Stop response (Factory setting: 1)
0: STOP A
1: STOP B
r9714[0] Load-side speed actual value [rpm]
Electrical speed of the motor. For induction motors, the mechanical speed is obtained
from the electrical speed and slip.
r9722.12 1 signal: SDI positive active
r9722.13 1 signal: SDI negative active
r9733 Effective setpoint speed limiting
[0] Positive setpoint limitation
[1] Negative setpoint limitation
[2] Absolute setpoint speed limitation
Commissioning
5.12 Setting extended functions
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
196 Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD