6.5.2 Selecting and deselecting SS1 when the motor is switched on
6.5.2.1 SS1 basic function
Select SS1
Function
1. The higher-level control selects the SS1 function via a fail-safe digital input or via
PROFIsafe safe communication.
2. If the motor is switched on when SS1 is selected, the inverter brakes the motor with the
OFF3 ramp-down time.
3. After the delay time, the inverter safely switches off the motor torque with the STO safety
function.
'HOD\
7KHPRWRUFRDVWVGRZQ
WRDVWDQGVWLOO
6SHHG
*UHHQRQ
W
W
66DFWLYH
672DFWLYH
<HOORZRQ
<HOORZRQ<HOORZIODVKHVVORZO\
W
'HVHOHFW66
212))
5HDG\WRVZLWFKRQ
/('5'<
/('6$)(
Figure 6-17 Braking behavior and diagnostics of the safety function SS1 (Safe Stop 1)
Inverter signal Parameter Included in the PROFI‐
safe telegram
Can be interconnec‐
ted with
F-DI F-DO
STO active (basic functions) r9773.1 ---
SS1 active (basic functions) r9773.6 ---
Deselect SS1 (basic functions) r9773.5 ---
Ready to switch on r0052.0 --- --- ---
ON/OFF1 r0054.0 --- --- ---
Operation
6.5 Safe Stop 1 (SS1)
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
238 Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD