You have not switched on the motor within 5 seconds
If you do not switch on the motor within 5 seconds after deselecting STO, the following happens:
The inverter goes back into the STO state.
The inverter no longer responds to the ON command.
The inverter outputs Alarm A01795.
To switch on the motor you must repeat the procedure described above.
Operation
6.6 Safely Limited Speed (SLS)
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD 267