Loading...
The feedback signal "SDI active" for pulse inhibit remains active
6SHHG
*UHHQRQ
<HOORZIODVKHVVORZO\
672DFWLYH
6',DFWLYH
'HVHOHFW672
6',GHVHOHFW
212))
6WDQGVWLOO
PRQLWRULQJ
5HDG\WRVZLWFKRQ
W
6',
W
W
/('5'<
/('6$)(
V
Figure 6-46 Switching the motor off and on when SDI is active
Procedure
To switch the motor on, proceed as follows:
1. Select STO (or SS1).
2. Deselect STO (or SS1) again.
3. After deselecting STO, wait until the inverter is "ready to switch on".
Alternatively: After deselecting STO, wait a certain time before switching on. We
recommend a wait time of 200 ms.
4. Switch on motor within 5 s after deselecting STO (ON command).
You have switched on the motor again.
Inverter signals Parameters Included in the PROFI‐
safe telegram
Can be interconnec‐
ted with
F-DI F-DO
STO active (extended functions) r9722.0 ---
Deselect STO (extended functions) r9720.0 ---
SDI+ active r9722.12 ---
SDI+ deselect r9720.12 ---
SDI- active r9722.13 ---
Deselect SDI- r9720.13 ---
ON/OFF1 r0054.0 --- --- ---
Ready to switch on r0052.0 --- --- ---

Operation
6.8 Safe Direction (SDI)
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
286 Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD

Table of Contents