Inverter signals Parameter Included in the PROFI‐
safe telegram
Can be interconnected
with
F-DI F-DO
STO active (basic functions) r9773.1 ---
STO deselection (basic functions) r9773.0 ---
STO cause, selection via terminal on the Power Module r9772.25 --- --- ---
STO active (extended functions) r9722.0 ---
Deselect STO (extended functions) r9720.0 ---
SSM feedback signal active (speed below limit value) r9722.15 ---
Operation
6.12 Selecting safety function when a safety function is active
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
308 Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD