The SBC safety function is standardized
The SBC function is defined in IEC/EN 61800-5-2:
"The SBC function supplies a safe output signal to control an external brake."
⇒ The SBC inverter function is in conformance with IEC/EN 61800-5-2.
Application example for the SBC function
Example Possible solution
After a hoisting gear stops, the inverter must close
the brake in order to minimize the risk of the load
falling.
Connect the motor holding brake to the
inverter via Safe Brake Relay.
Select STO when the drive stops.
Description
3.7 An overview of the principle of operation of the safety functions
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD 35