6.9 Deviations from the standard I/O addressing schematic
6.9.1
Overview
Use of user-specific adaptations of an addressing schematic
In some cases when configuring in the TIA Portal, the preset default I/O addresses for the
communication with the drive have already been assigned, e.g.:
If you added telegrams that are not part of the default telegram configuration.
If you have subsequently changed the size of the process image.
If you have subsequently changed the Safety Integrated mode.
If you have subsequently added NX modules.
A message is then displayed in the TIA Portal, indicating that you must check the telegram
configuration. The actual procedure depends on whether suitable alternative I/O addresses
could be assigned:
Suitable alternative I/O addresses have been assigned in the TIA Portal that do not match
the standard I/O addresses in the machine data of the NCU. In this case, the I/O addresses
in the TIA Portal must be aligned with the I/O addresses in the machine data of the NCU
(Page 143).
There are not enough suitable I/O addresses available in the TIA Portal. In this case, you
must release suitable I/O addresses in the TIA Portal, re-assign them and then align them
with the I/O addresses in the machine data of the NCU. See: Availability of suitable I/O
addresses (Page 145).
If you do not want to make these settings at this time, and have not saved the project, you can
undo the changes: Click "Undo" in the toolbar.
See also
Matching I/O addresses for use of the optimized I/O addressing schematic (Page 142)
Changing the addressing schematic (Page 118)
6.9.2 Matching of deviating I/O addresses
6.9.2.1 Matching I/O addresses for use of the optimized I/O addressing schematic
If you use the optimized I/O addressing schematic, you must activate it in TIA Portal and you
must enter the I/O addresses in the machine data, e.g. via SINUMERIK Operate.
Configuring telegrams and drive units
6.9 Deviations from the standard I/O addressing schematic
SINUMERIK STEP 7 Toolbox V15.1
142 Configuration Manual, 12/2018, A5E46279635B AA

Table of Contents

Other manuals for Siemens SINUMERIK 840D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl and is the answer not in the manual?

Siemens SINUMERIK 840D sl Specifications

General IconGeneral
Control TypeCNC
Number of AxesUp to 31
Max Number of Channels10
InterfacesEthernet, PROFIBUS, PROFINET, USB
Interpolation5-axis interpolation
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
DisplayTFT color display, various sizes
Programming LanguagesDIN/ISO
Safety FeaturesSafety Integrated
PLCIntegrated PLC S7-300
Drive InterfaceSINAMICS S120
Data StorageCF card, USB
Operating SystemWindows-based

Related product manuals