3.4 Establish the communication connection
Procedure
To establish a communication connection between two devices, proceed as follows:
1. In the "Online" menu, select the "Accessible devices" command.
2. In the drop-down lists "Type of PG/PC interface" and "PG/PC interface", search for the
interface used.
If no devices are accessible at an interface, the connecting line between the PG/PC and the
device is interrupted. If devices are accessible, the connecting line is shown and the devices
accessible at the selected interface of the PG/PC are displayed in a list.
Configuring the NCU
3.4 Establish the communication connection
SINUMERIK STEP 7 Toolbox V15.1
Configuration Manual, 12/2018, A5E46279635B AA 37

Table of Contents

Other manuals for Siemens SINUMERIK 840D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl and is the answer not in the manual?

Siemens SINUMERIK 840D sl Specifications

General IconGeneral
Control TypeCNC
Number of AxesUp to 31
Max Number of Channels10
InterfacesEthernet, PROFIBUS, PROFINET, USB
Interpolation5-axis interpolation
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
DisplayTFT color display, various sizes
Programming LanguagesDIN/ISO
Safety FeaturesSafety Integrated
PLCIntegrated PLC S7-300
Drive InterfaceSINAMICS S120
Data StorageCF card, USB
Operating SystemWindows-based