3.6.5 Creating a PLC commissioning archive
Requirement
If possible, the "Program blocks" folder should not contain any program blocks of not
activated axes/spindles or the tool management.
You can also save unused program blocks in the archive, although this extends the time
required for creating and loading the archive.
The
data carrier to be used or storage location is available and has sufficient storage space.
Note
Handling of F-blocks for SINUMERIK archives
The handling of F-blocks depends on the used Safety Integrated mode:
If
Safety Integrated is inactive or Safety Integrated (SPL) is active, F-blocks are not stored
in the SINUMERIK archive.
In Safety Integrated plus (F-PLC) mode, F-blocks are saved in PLC commissioning
archives.
Note the additional information in the Readme file for SINUMERIK Toolbox: "Start >
Siemens Automation > Documentation > Readmes > German".