Configuring networks
5
5.1 Configuring an Ethernet Interface
Procedure
In order to set the Ethernet interface, proceed as follows:
1. In the network view, click the CP in the basic rack of the NCU.
2. Under the "Properties" tab in the inspector window, select the "PN/IE interface > Ethernet
addresses" entry.
3. Set the IP address matching your real configuration. If the PG/PC is connected to X127, the
following IP address applies:
Hardware factory setting on the NCU for socket X127
IP address: 192.168.215.1
Subnet mask: 255.255.255.0
SINUMERIK STEP 7 Toolbox V15.1
Configuration Manual, 12/2018, A5E46279635B AA 93

Table of Contents

Other manuals for Siemens SINUMERIK 840D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl and is the answer not in the manual?

Siemens SINUMERIK 840D sl Specifications

General IconGeneral
Control TypeCNC
Number of AxesUp to 31
Max Number of Channels10
InterfacesEthernet, PROFIBUS, PROFINET, USB
Interpolation5-axis interpolation
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
DisplayTFT color display, various sizes
Programming LanguagesDIN/ISO
Safety FeaturesSafety Integrated
PLCIntegrated PLC S7-300
Drive InterfaceSINAMICS S120
Data StorageCF card, USB
Operating SystemWindows-based

Related product manuals