05.91 11 Programming of Cycles
11.12 @ Code table
@ code CL 800 instruction Function
@71b
Value
1
Value
2
Value
3
Value
4
PELG ( Value1 , Value2 )
= ( Value3 , Value4 )
Load ELG speed ratio
parameters; leading axis is
an axis
@71c
Value
1
Value
2
Value
3
Value
4
PELG ( Value1 , Value2 )
= ( Value3 , Value4 )
Load ELG speed ratio
parameters; leading axis is a
spindle
@720
Var
Value
Var =MEAS M Value Inprocess measurement
Var: Data stored starting
at
Value: No. of measure-
ment input; 1 or 2
@f00 Var 1 Var 2 Var 1 =PP CLEAR
( Var 2 );
Clear program
Var 1 : Input data starting
at Var 1
Var 2 : Output data starting
at Var 2
@f01 Var 1 Var 2 Var 1 =PP SELECT EDIT
( Var 2 );
Select program for editing
Var 1 : Input data starting
at Var 1
Var 2 : Output data starting
at Var 2
@f02 Var 1 Var 2 Var 1 =PP CREATE
( Var 2 );
Open program
Var 1 : Input data starting
at Var 1
Var 2 : Output data starting
at Var 2
@f03 Var 1 PP SELECT SIM ( Var 1 ); Select program for simulation
Var 1 : Input data starting
at Var 1
@f04 Var 1 Var 2 Not yet defined Disable program for
execution
Var 1 : Input data starting
at Var 1
Var 2 : Output data starting
at Var 2
_______
Explanation of symbols:
x compare operator vop 1) Not at CL 800 level
0: . . . . no condition 2) ”Condition”: a)
Var
=Boolean variable
1:= . . . . equal to b)
Var
.
Const
=Bit from pattern
2: . . . . not equal to c)
Var
”Vop”
Value
3: . . . . greater than d) Extended condition
4: = . . . . greater than or equal to
5: . . . . less than 3) Option
6:= . . . . less than or equal to
7: . . . . true 4) No pointers possible,
8: . . . . not on CL 800 level only
Const
can be specified
© Siemens AG 1991 All Rights Reserved 6ZB5 410-0HD02 11–79
SINUMERIK 880, (PG)