Connection
6.7 Connecting the infeed system (option)
SIRIUS 3RM1 motor starter
Manual, 06/2016, A5E0345285095020A/RS-AE/005
121
6.7
Connecting the infeed system (option)
DANGER
Hazardous voltage.
Will cause death or serious injury.
Turn off and lock out all power supplying this device before working on this device.
Requirements
Please note the following requirements for mounting the 3RM19 infeed system:
Make sure the rated operational current of the infeed system (IEC: 25 A; UL: 16 A) is not
exceeded.
The 3RM1 motor starters are mounted next to each other on a mounting rail or a level
mounting surface.
The mounting system is only suitable for main current terminals with screw connections.
Cross-tip screwdriver size PZ 1 x 80
For suitable connection cross-sections of the cables for the infeed terminal, see the
Chapter "Connection cross sections (Page 141)".