Mounting
7.3 Assembly and disassembly with different mounting systems
SIRIUS - SIRIUS 3RA load feeders
Manual, 09/2016, A5E03656507520A/RS-AB/003
103
⑤ Screw the main conductor terminals tight.
⑥ Snap the reversing starter onto the busbar adapter.
⑦ Connect the connection cables to the applicable main conductor terminals.
⑧ Slide the positioning piece from below onto the busbar adapter until it engages at the bottom on the contactor.
Figure 7-44 Mounting on the busbar adapter (reversing starter, screw-type connection system, size S0)