EasyManua.ls Logo

Siemens SITRANS F MAG 8000 Standard - Page 154

Siemens SITRANS F MAG 8000 Standard
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Param‐
eter ID
Meter
version
Display
view
Parameter/data type Factory settings Data range
Fixed parameter or meter data that are not changeable
833 Advanced R10 Previous settling date PS3 production date and
time
year-month-day T hours:mi‐
nutes:seconds
834 Advanced R10 Previous totalizer 1 value 0
840 Advanced Tariff control mode Off Off / time / range / combination
841 Advanced R7 Date of tariff reset PS3 production date and
time
year-month-day T hours:mi‐
nutes:seconds
842 Advanced - Reset tariff values No Yes / No
Value is reset to "No" when up‐
loading device parameters to pc
after command execution
843 Advanced R1 Tariff1 volume 1 0
844 Advanced R1 Tariff1 period time end 360 min = 6:00 [24:00] 0 to 1439 minutes (23:59)
845 Advanced R1 Tariff1 upper limit range 15% 0 to 100% Qn (Q3)
846 Advanced R2 Tariff2 volume 2 0
847 Advanced R2 Tariff2 period time end 540 min = 9:00 [24:00] 0 to 1439 minutes (23:59)
848 Advanced R2 Tariff2 upper limit range 30% 0 to 100% Qn (Q3)
849 Advanced R3 Tariff3 volume 3 0
850 Advanced R3 Tarif3 period time end 720 min = 12:00 [24:00] 0 to 1439 minutes (23:59)
851 Advanced R3 Tariff3 upper limit range 45% 0 to 100% Qn (Q3)
852 Advanced R4 Tariff4 volume 4 0
853 Advanced R4 Tariff4 period time end 1080min=18:00 [24:00] 0 to 1439 minutes (23:59)
854 Advanced R4 Tariff4 upper limit range 60% 0 to 100% Qn (Q3)
855 Advanced R5 Tariff5 volume 5 0
856 Advanced R5 Tariff5 period time end 1260 min = 21:00 [24:00] 0 to 1439 minutes (23:59)
857 Advanced R5 Tariff5 upper limit range 80% 0 to 100% Qn (Q3)
858 Advanced R6 Tariff6 volume 6 0
860 Advanced - Reset date of statistic inf. PS3 production date and
time
year- month-day T hours:mi‐
nutes:seconds
861 Advanced - Reset statistic information No Yes / No
Value is reset to "No" when up‐
loading device parameters to pc
after command execution
862 Advanced St2 Lowest flowrate 0
863 Advanced St2 Date of lowest flowrate PS3 production date and
time
year-month-day T hours:mi‐
nutes:seconds
864 Advanced St3 Highest flowrate 0
865 Advanced St3 Date of highest flowrate PS3 production date and
time
year-month-day T hours:mi‐
nutes:seconds
866 Advanced St5 Lowest day consumption 0
867 Advanced - Date of lowest day con‐
sumption
PS3 production date and
time
year-month-day T hours:mi‐
nutes:seconds
868 Advanced St6 Highest day consumption 0
869 Advanced - Date of highest day con‐
sumption
PS3 production date and
time
year-month-day T hours:mi‐
nutes:seconds
Appendix
C.2 Parameter lists
SITRANS MAG 8000
154 Operating Instructions, 11/2018, A5E03071515-AE

Table of Contents

Related product manuals