Appendix A
A.1 Modbus, EIP, HART & N2 Profile Mappings
F US Clamp-on Communications Protocol Manual
Hardware Installation Manual, 11/2015, A5E34981613-AC
129
C1 Aeration Units
30609
8
String
String_In
44
UINT16
n/a
BD(Byte)
89
8
C1 Status
/Alarms: Spacing
10021 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 1 1
C1 Status
/Alarms: Empty
10022 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 3 1
C1 Status
/Alarms: Rate
10023 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 4 1
C1 Status
/Alarms: Fault
10024 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 5 1
C1 Status
/Alarms: Aeration
10025 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 6 1
C1 Status
/Alarms: Memory
10026 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 7 1
C1 Status
/Alarms: Makeup
10027 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 8 1
C1 Status
/Alarms: Interface
10028 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 9 1
C1 Status
/Alarms: Zeroma-
tic
10030 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 2 1
C1 Delta Time
30179
4
Real
Analog_In
19
Float
n/a
ADF(Float)
14
1
C1 Delta Time
Units
30629 8 String String_In 48 UINT16 n/a BD(Byte) 97 8
C2 Site ID
30505
8
String
String_In
52
UINT16
n/a
BD(Byte)
105
8
C2 Avg Energy
Rate
30203 4 Real Analog_In 20 Float 129 41-29h Q ADF(Float) 15 1
C2 Inst.Energy
Rate
30197 4 Real Analog_In 21 Float n/a ADF(Float) 16 1
C2 Energy Rate
Units
30657 8 String String_In 56 UINT16 131 41-29h BD(Byte) 113 8
C2 Energy Total
30209
4
Real
Analog_In
22
Float
129
44-2Ch
ADF(Float)
17
1
C2 EnergyTotal
Units
30665 8 String String_In 60 UINT16 131 44-2Ch BD(Byte) 121 8
C2 Inst.Flow
Rate
30111 4 Real Analog_In 23 Float 129 7-07h ADF(Float) 18 1
C2 Avg Flow
Rate
30123 4 Real Analog_In 24 Float 129 2-02h T ADF(Float) 19 1
C2 Flow Rate
Units
30521 8 String String_In 64 UINT16 131 2-02h BD(Byte) 129 8
C2 Total
30147
4
Real
Analog_In
25
Float
129
35-23h
ADF(Float)
20
1
C2 Total Units
30561
8
String
String_In
68
UINT16
131
35-23h
BD(Byte)
137
8
C2 Supply Temp
30305
4
Real
Analog_In
26
Float
n/a
ADF(Float)
21
1
C2 Supply Temp
Units
30777 8 String String_In 72 UINT16 n/a BD(Byte) 145 8
C2 Return Temp
30311
4
Real
Analog_In
27
Float
n/a
ADF(Float)
22
1
C2 Return Temp
Units
30785 8 String String_In 76 UINT16 n/a BD(Byte) 153 8
C2 Temp
Difference
30317 4 Real Analog_In 28 Float n/a ADF(Float) 23 1