Appendix A
A.1 Modbus, EIP, HART & N2 Profile Mappings
F US Clamp-on Communications Protocol Manual
148 Hardware Installation Manual, 11/2015, A5E34981613-AC
A.1.35
Profile 34
Profile 34 (FUE1010-5EN04-5.04.05-DPCO)
Data Description
Modbus
Ethernet/IP
HART
N2
Reg
Bytes
Type
Tag Name
OS
Format
CMD
VAR
Type
Ad
Sz
Site ID
30501
8
String
String_In
0
UINT16
n/a
BD(Byte)
1
8
Date: Year
30101
2
Integer
Analog_In
0
Float
n/a
ADI(Int)
1
1
Date: Month
30102
2
Integer
Analog_In
1
Float
n/a
ADI(Int)
2
1
Date: Day
30103
2
Integer
Analog_In
2
Float
n/a
ADI(Int)
3
1
Time: Hour
30104
2
Integer
Analog_In
3
Float
n/a
ADI(Int)
4
1
Time: Minute
30105
2
Integer
Analog_In
4
Float
n/a
ADI(Int)
5
1
Time: Second
30106
2
Integer
Analog_In
5
Float
n/a
ADI(Int)
6
1
Avg Energy Rate
30199
4
Real
Analog_In
6
Float
129
39-27h T
ADF(Float)
1
1
Inst.Energy Rate 30193 4 Real Analog_In 7 Float n/a ADF(Float) 2 1
Energy Rate
Units
30653 8 String String_In 4 UINT16 131 39-27h BD(Byte) 9 8
Energy Total
30205
4
Real
Analog_In
8
Float
129
42-2Ah Q
ADF(Float)
3
1
EnergyTotal
Units
30661 8 String String_In 8 UINT16 131 42-2Ah BD(Byte) 17 8
Inst.Flow Rate
Path 1
30109 4 Real Analog_In 9 Float 129 10-0Ah ADF(Float) 4 1
Inst.Flow Rate
Path 2
30111 4 Real Analog_In 10 Float 129 11-0Bh ADF(Float) 5 1
Inst.Flow Rate
30107
4
Real
Analog_In
11
Float
n/a
ADF(Float)
6
1
Avg Flow Rate
30119
4
Real
Analog_In
12
Float
129
0-00h P
ADF(Float)
7
1
Flow Rate Units
30517
8
String
String_In
12
UINT16
131
0-00h
BD(Byte)
25
8
Raw Flow Path 1
30133
4
Real
Analog_In
13
Float
n/a
ADF(Float)
8
1
Raw Flow Path 2
30135
4
Real
Analog_In
14
Float
n/a
ADF(Float)
9
1
Raw Flow Units
30537
8
String
String_In
16
UINT16
n/a
BD(Byte)
33
8
Total
30143
4
Real
Analog_In
15
Float
129
33-21h S
ADF(Float)
10
1
Total Units
30557
8
String
String_In
20
UINT16
131
33-21h
BD(Byte)
41
8
Sonic Vel Path 1
30157
4
Real
Analog_In
16
Float
n/a
ADF(Float)
11
1
Sonic Vel Path 2
30159
4
Real
Analog_In
17
Float
n/a
ADF(Float)
12
1
Sonic Vel
30155
4
Real
Analog_In
18
Float
n/a
ADF(Float)
13
1
Sonic Vel Units
30577
8
String
String_In
24
UINT16
n/a
BD(Byte)
49
8
Supply Temp
30301
4
Real
Analog_In
19
Float
n/a
ADF(Float)
14
1
Supply Temp
Units
30773 8 String String_In 28 UINT16 n/a BD(Byte) 57 8
Return Temp
30307
4
Real
Analog_In
20
Float
n/a
ADF(Float)
15
1
Return Temp
Units
30781 8 String String_In 32 UINT16 n/a BD(Byte) 65 8
Temp Difference
30313
4
Real
Analog_In
21
Float
n/a
ADF(Float)
16
1
Temp Diff Units
30789
8
String
String_In
36
UINT16
n/a
BD(Byte)
73
8
Signal Strength
Path 1
30167 2 Integer Analog_In 22 Float n/a ADF(Float) 17 1
Signal Strength
Path 2
30168 2 Integer Analog_In 23 Float n/a ADF(Float) 18 1
Signal Strength
30165
2
Integer
Analog_In
24
Float
n/a
ADF(Float)
19
1

Table of Contents