EasyManua.ls Logo

Siemens SITRANS F US - Profile 39

Siemens SITRANS F US
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix A
A.1 Modbus, EIP, HART & N2 Profile Mappings
F US Clamp-on Communications Protocol Manual
Hardware Installation Manual, 11/2015, A5E34981613-AC
159
A.1.40
Profile 39
Profile 39 (FUH1010-5BN02-5.04.05-1CO2CO)
Data Description
Modbus
Ethernet/IP
HART
N2
Reg
Bytes
Type
Tag Name
OS
Format
CMD
VAR
Type
Ad
Sz
C1 Site ID
30501
8
String
String_In
0
UINT16
n/a
BD(Byte)
1
8
Date: Year
30101
2
Integer
Analog_In
0
Float
n/a
ADI(Int)
1
1
Date: Month
30102
2
Integer
Analog_In
1
Float
n/a
ADI(Int)
2
1
Date: Day
30103
2
Integer
Analog_In
2
Float
n/a
ADI(Int)
3
1
Time: Hour
30104
2
Integer
Analog_In
3
Float
n/a
ADI(Int)
4
1
Time: Minute
30105
2
Integer
Analog_In
4
Float
n/a
ADI(Int)
5
1
Time: Second
30106
2
Integer
Analog_In
5
Float
n/a
ADI(Int)
6
1
C1 Raw Flow
30133
4
Real
Analog_In
6
Float
n/a
ADF(Float)
1
1
C1 Raw Flow
Units
30537 8 String String_In 4 UINT16 n/a BD(Byte) 9 8
C1 Sonic Vel
30157
4
Real
Analog_In
7
Float
n/a
ADF(Float)
2
1
C1 Sonic Vel
Units
30577 8 String String_In 8 UINT16 n/a BD(Byte) 17 8
C1 Signal
Strength
30167 2 Integer Analog_In 8 Float n/a ADF(Float) 3 1
C1 Sig Strength
Units
30593 8 String String_In 12 UINT16 n/a BD(Byte) 25 8
C1 Aeration
30172
2
Integer
Analog_In
9
Float
n/a
ADF(Float)
4
1
C1 Aeration Units
30609
8
String
String_In
16
UINT16
n/a
BD(Byte)
33
8
C1 Liquid Name
30745
8
String
String_In
20
UINT16
n/a
BD(Byte)
41
8
C1 Liquident
30231
4
Real
Analog_In
10
Float
n/a
ADF(Float)
5
1
C1 Liquident
Units
30677 8 String String_In 24 UINT16 n/a BD(Byte) 49 8
C1 Specific
Gravity
30239 4 Real Analog_In 11 Float 129 15-0Fh P ADF(Float) 6 1
C1 S.G. Units
30689
8
String
String_In
28
UINT16
131
15-0Fh
BD(Byte)
57
8
C1 API
30249
4
Real
Analog_In
12
Float
129
18-12h S
ADF(Float)
7
1
C1 API Units
30705
8
String
String_In
32
UINT16
131
18-12h
BD(Byte)
65
8
C1 Kg/m3
30255
4
Real
Analog_In
13
Float
129
21-15h
ADF(Float)
8
1
C1 Kg/m3 Units
30713
8
String
String_In
36
UINT16
131
21-15h
BD(Byte)
73
8
C1 Base S.G.
30261
4
Real
Analog_In
14
Float
129
24-18h
ADF(Float)
9
1
C1 Base S.G.
Units
30721 8 String String_In 40 UINT16 131 24-18h BD(Byte) 81 8
C1 Base API
30267
4
Real
Analog_In
15
Float
129
27-1Bh
ADF(Float)
10
1
C1 Base API
Units
30729 8 String String_In 44 UINT16 131 27-1Bh BD(Byte) 89 8
C1 Base Kg/m3
30273
4
Real
Analog_In
16
Float
129
30-1Eh
ADF(Float)
11
1
C1 Base Kg/m3
Units
30737 8 String String_In 48 UINT16 131 30-1Eh BD(Byte) 97 8
C1 Status
/Alarms: Spacing
10021 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 1 1
C1 Status
/Alarms: Empty
10022 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 3 1

Table of Contents

Other manuals for Siemens SITRANS F US