Appendix A
A.1 Modbus, EIP, HART & N2 Profile Mappings
F US Clamp-on Communications Protocol Manual
160 Hardware Installation Manual, 11/2015, A5E34981613-AC
C1 Status
/Alarms: Rate
10023 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 4 1
C1 Status
/Alarms: Fault
10024 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 5 1
C1 Status
/Alarms: Aeration
10025 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 6 1
C1 Status
/Alarms: Memory
10026 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 7 1
C1 Status
/Alarms: Makeup
10027 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 8 1
C1 Status
/Alarms: Interface
10028 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 9 1
C1 Status
/Alarms: Pig
10029 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 10 1
C1 Status
/Alarms: Zeroma-
tic
10030 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 2 1
Temperature 1
30293
4
Real
Analog_In
17
Float
n/a
ADF(Float)
12
1
Temp 1 Units
30757
8
String
String_In
52
UINT16
n/a
BD(Byte)
105
8
Analog Input 1
30277
4
Real
Analog_In
18
Float
n/a
ADF(Float)
13
1
AI 1 Units
30797
8
String
String_In
56
UINT16
n/a
BD(Byte)
113
8
Analog Input 2
30279
4
Real
Analog_In
19
Float
n/a
ADF(Float)
14
1
AI 2 Units
30801
8
String
String_In
60
UINT16
n/a
BD(Byte)
121
8
C2 Site ID
30505
8
String
String_In
64
UINT16
n/a
BD(Byte)
129
8
C2 Raw Flow
30135
4
Real
Analog_In
20
Float
n/a
ADF(Float)
15
1
C2 Raw Flow
Units
30541 8 String String_In 68 UINT16 n/a BD(Byte) 137
8
C2 Sonic Vel
30159
4
Real
Analog_In
21
Float
n/a
ADF(Float)
16
1
C2 Sonic Vel
Units
30581 8 String String_In 72 UINT16 n/a BD(Byte) 145
8
C2 Signal
Strength
30168 2 Integer Analog_In 22 Float n/a ADF(Float) 17 1
C2 Sig Strength
Units
30597 8 String String_In 76 UINT16 n/a BD(Byte) 153
8
C2 Aeration
30173
2
Integer
Analog_In
23
Float
n/a
ADF(Float)
18
1
C2 Aeration Units 30613 8 String String_In 80 UINT16 n/a BD(Byte) 161
8
C2 Liquid Name
30749
8
String
String_In
84
UINT16
n/a
BD(Byte)
169
8
C2 Liquident
30233
4
Real
Analog_In
24
Float
n/a
ADF(Float)
19
1
C2 Liquident
Units
30681 8 String String_In 88 UINT16 n/a BD(Byte) 177
8
C2 Specific
Gravity
30241 4 Real Analog_In 25 Float 129 16-10h T ADF(Float) 20 1
C2 S.G. Units
30693
8
String
String_In
92
UINT16
131
16-10h
BD(Byte)
185
8
C2 API
30251
4
Real
Analog_In
26
Float
129
19-13h Q
ADF(Float)
21
1
C2 API Units
30709
8
String
String_In
96
UINT16
131
19-13h
BD(Byte)
193
8
C2 Kg/m3
30257
4
Real
Analog_In
27
Float
129
22-16h
ADF(Float)
22
1
C2 Kg/m3 Units
30717
8
String
String_In
100
UINT16
131
22-16h
BD(Byte)
201
8
C2 Base S.G.
30263
4
Real
Analog_In
28
Float
129
25-19h
ADF(Float)
23
1