HART Communications
4.1 Universal HART Commands
F US Clamp-on Communications Protocol Manual
40 Hardware Installation Manual, 11/2015, A5E34981613-AC
Table 4- 9 Command 9 - Read Device Variable with Status
Extended Field Device Status
<refer to common table 17>
Slot 0: Device Variable Code
Slot 0: Device Variable Classification
Slot 0: Device Variable Units Code
< write units CMD 35 or 44>
Slot 0: Device Variable Value
Slot 0: Device Variable Status
<Device Status Common Table>
Slot 1: Device Variable Code
Slot 1: Device Variable Classification
Slot 1: Device Variable Units Code
<select SV Units CMD 161>
Slot 1: Device Variable Value
Slot 1: Device Variable Status
<Device Status Common Table>
Slot 2: Device Variable Code
Slot 2: Device Variable Classification 18 Enum
0-not classified
Slot 2: Device Variable Units Code
<select TV Units CMD 163>
Slot 2: Device Variable Value 20-23 Float
Slot 2: Device Variable Status
<Device Status Common Table>
Slot 3: Device Variable Code
249 <Quaternary Variable>
Slot 3: Device Variable Classification
Slot 3: Device Variable Units Code
<select QV Units CMD 165>
Slot 3: Device Variable Value
Slot 3: Device Variable Status
<Device Status Common Table>
Table 4- 10 Command 11 - Read Unique identifier Associated with Tag
Minimum number of Preambles
HART Protocol Major Revision Number
<5 most significant bits>
Physical Signaling Code 7 0
<3 least significant bits>
Device ID 9-11
<unique ID for each >
Minimum number of preambles
Maximum number of Device Variables
Configuration Change Counter
<increments with each write>
Extended Field Device Status
Manufacturer Identification Code
Private Label Distribution Code
Process Automation Device