Appendix A
A.1 Modbus, EIP, HART & N2 Profile Mappings
F US Clamp-on Communications Protocol Manual
76 Hardware Installation Manual, 11/2015, A5E34981613-AC
Profile 7 (FUS1010-5N03-5.04.05-1CO2RF)
C1 Inst.Flow
30109 4 Real Analog_In 6 Float 129 6-06h ADF(Float) 1 1
C1 Avg Flow
Rate
30121 4 Real Analog_In 7 Float 129 1-01h P ADF(Float) 2 1
C1 Flow Rate
30517 8 String String_In 4 UINT16 131 1-01h BD(Byte) 9 8
C1 Raw Flow
30537 8 String String_In 8 UINT16 n/a BD(Byte) 17 8
C1 Sonic Vel
30577 8 String String_In 16 UINT16 n/a BD(Byte) 33 8
C1 Signal
30167 2 Integer Analog_In 11 Float n/a ADF(Float) 6 1
C1 Sig Strength
30593 8 String String_In 20 UINT16 n/a BD(Byte) 41 8
C1 Status
10021 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 1 1
C1 Status
10022 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 3 1
C1 Status
10023 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 4 1
C1 Status
10024 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 5 1
C1 Status
10025 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 6 1
C1 Status
10026 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 7 1
C1 Status
10027 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 8 1
C1 Status
10028 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 9 1