Appendix A
A.1 Modbus, EIP, HART & N2 Profile Mappings
F US Clamp-on Communications Protocol Manual
152 Hardware Installation Manual, 11/2015, A5E34981613-AC
A.1.37
Profile 36
Profile 36 (FUH1010-5PVN02-5.04.05-DPCO)
Data Description
Modbus
Ethernet/IP
HART
N2
Reg
Bytes
Type
Tag Name
OS
Format
CMD
VAR
Type
Ad
Sz
Site ID
30501
8
String
String_In
0
UINT16
n/a
BD(Byte)
1
8
Date: Year
30101
2
Integer
Analog_In
0
Float
n/a
ADI(Int)
1
1
Date: Month
30102
2
Integer
Analog_In
1
Float
n/a
ADI(Int)
2
1
Date: Day
30103
2
Integer
Analog_In
2
Float
n/a
ADI(Int)
3
1
Time: Hour
30104
2
Integer
Analog_In
3
Float
n/a
ADI(Int)
4
1
Time: Minute
30105
2
Integer
Analog_In
4
Float
n/a
ADI(Int)
5
1
Time: Second
30106
2
Integer
Analog_In
5
Float
n/a
ADI(Int)
6
1
Inst.Flow Rate
Path 1
30109 4 Real Analog_In 6 Float 129 10-0Ah T ADF(Float) 1 1
Inst.Flow Rate
Path 2
30111 4 Real Analog_In 7 Float 129 11-0Bh Q ADF(Float) 2 1
Inst.Flow Rate
30107
4
Real
Analog_In
8
Float
n/a
ADF(Float)
3
1
Avg Flow Rate 30119 4 Real Analog_In 9 Float 129 0-00h P ADF(Float) 4 1
Flow Rate Units
30517
8
String
String_In
4
UINT16
131
0-00h
BD(Byte)
9
8
Raw Flow Path 1
30133
4
Real
Analog_In
10
Float
n/a
ADF(Float)
5
1
Raw Flow Path 2
30135
4
Real
Analog_In
11
Float
n/a
ADF(Float)
6
1
Raw Flow Units
30537
8
String
String_In
8
UINT16
n/a
BD(Byte)
17
8
Total
30143
4
Real
Analog_In
12
Float
129
33-21h S
ADF(Float)
7
1
Total Units
30557
8
String
String_In
12
UINT16
131
33-21h
BD(Byte)
25
8
Sonic Vel Path 1
30157
4
Real
Analog_In
13
Float
n/a
ADF(Float)
8
1
Sonic Vel Path 2
30159
4
Real
Analog_In
14
Float
n/a
ADF(Float)
9
1
Sonic Vel
30155
4
Real
Analog_In
15
Float
n/a
ADF(Float)
10
1
Sonic Vel Units
30577
8
String
String_In
16
UINT16
n/a
BD(Byte)
33
8
Signal Strength
Path 1
30167 2 Integer Analog_In 16 Float n/a ADF(Float) 11 1
Signal Strength
Path 2
30168 2 Integer Analog_In 17 Float n/a ADF(Float) 12 1
Signal Strength
30165
2
Integer
Analog_In
18
Float
n/a
ADF(Float)
13
1
Sig Strength
Units
30593 8 String String_In 20 UINT16 n/a BD(Byte) 41 8
Aeration 30171 2 Integer Analog_In 19 Float n/a ADF(Float) 14 1
Aeration Units
30609
8
String
String_In
24
UINT16
n/a
BD(Byte)
49
8
Liquident 30229 4 Real Analog_In 20 Float n/a ADF(Float) 15 1
Liquident Units
30677
8
String
String_In
28
UINT16
n/a
BD(Byte)
57
8
Viscosity
30235
4
Real
Analog_In
21
Float
n/a
ADF(Float)
16
1
Viscosity Units
30685
8
String
String_In
32
UINT16
n/a
BD(Byte)
65
8
Status: Spacing
Path 1
10021 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 1 1
Status: Empty
Path 1
10022 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 3 1
Status: Rate
Path 1
10023 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 4 1

Table of Contents