Installing/Mounting
2.2 F US Clamp-on Communications Module Installation
F US Clamp-on Communications Protocol Manual
16 Hardware Installation Manual, 11/2015, A5E34981613-AC
Table 2- 2 Profile Selection: 1 - 46
Profile Selection
B1
B2
B3
B4
B5
B6
Profile
Flowmeter Firmware Version & Configuration
Off
Off
Off
Off
Off
Off
profile 1
5N01-5.04.05 CH1: Clamp-On
On
Off
Off
Off
Off
Off
profile 2
5N01-5.04.05 CH1: Reflexor
Off
On
Off
Off
Off
Off
profile 3
5N02-5.04.05 CH1: Clamp-On
On
On
Off
Off
Off
Off
profile 4
5N02-5.04.05 CH1: Reflexor
Off
Off
On
Off
Off
Off
profile 5
5N03-5.04.05 CH1: Clamp-On CH2: Clamp-On
On
Off
On
Off
Off
Off
profile 6
5N03-5.04.05 CH1: Reflexor CH2: Reflexor
Off
On
On
Off
Off
Off
profile 7
5N03-5.04.05 CH1: Clamp-on CH2: Reflexor
On
On
On
Off
Off
Off
profile 8
5N03-5.04.05 Dual Path: Clamp-On
Off
Off
Off
On
Off
Off
profile 9
5N03-5.04.05 CH1+2: Clamp-On
On
Off
Off
On
Off
Off
profile 10
5N03-5.04.05 CH1-2: Clamp-On
Off
On
Off
On
Off
Off
profile 11
5N04-5.04.05 CH1: Clamp-On CH2: Clamp-On
On On Off On Off Off profile 12 5N04-5.04.05 CH1: Reflexor CH2: Reflexor
Off
Off
On
On
Off
Off
profile 13
5N04-5.04.05 CH1: Clamp-On CH2: Reflexor
On Off On On Off On profile 14 5N04-5.04.05 Dual Path: Clamp-On
Off
On
On
On
Off
Off
profile 15
5N04-5.04.05 CH1+2: Clamp-On
On
On
On
On
Off
Off
profile 16
5N04-5.04.05 CH1-2: Clamp-On
Off
Off
Off
Off
On
Off
profile 17
5MN01-5.04.05 4 Channel Flow: Clamp-On
On
Off
Off
Off
On
Off
profile 18
5MN01-5.04.05 CH5: Clamp-On
Off
On
Off
Off
On
Off
profile 19
5MN01-5.04.05 Quad Path: Clamp-On
On
On
Off
Off
On
Off
profile 20
5MN02-5.04.05 4 Channel Flow: Clamp-On
Off
Off
On
Off
On
Off
profile 21
5MN02-5.04.05 CH5: Clamp-On
On
Off
On
Off
On
Off
profile 22
5MN02-5.04.05 Quad Path: Clamp-On
Off
On
On
Off
On
Off
profile 23
5EN02-5.04.05 Ch1: Clamp-On
On
On
On
Off
On
Off
profile 24
5EN02-5.04.05 Ch1: Reflexor
Off
Off
Off
On
On
Off
profile 25
5EN03-5.04.05 Ch1: Clamp-On Ch2: Clamp-On
On
Off
Off
On
On
Off
profile 26
5EN03-5.04.05 Ch1:Reflexor Ch2: Reflexor
Off
On
Off
On
On
Off
profile 27
5EN03-5.04.05 Ch1: Clamp-On Ch2: Reflexor
On
On
Off
On
On
Off
profile 28
5EN03-5.04.05 Dual Path: Clamp-On
Off
Off
On
On
On
Off
profile 29
5EN03-5.04.05 Ch1+2: Clamp-On
On
Off
On
On
On
Off
profile 30
5EN04-5.04.05 Ch1: Clamp-On Ch2: Clamp-On
Off
On
On
On
On
Off
profile 31
5EN04-5.04.05 Ch1: Reflexor Ch2: Reflexor
On
On
On
On
On
Off
profile 32
5EN04-5.04.05 Ch1: Clamp On Ch2: Reflexor
Off Off Off Off Off On profile 33 5EN04-5.04.05 Ch1+2: Clamp-On
On
Off
Off
Off
Off
On
profile 34
5EN04-5.04.05 Dual Path: Clamp-On
Off On Off Off Off On profile 35 5PVN01-5.04.05 CH1: Clamp-On
On
On
Off
Off
Off
On
profile 36
5PVN02-5.04.05 Dual Path: Clamp-On
Off
Off
On
Off
Off
On
profile 37
5PVN03-5.04.05 Dual Path: Clamp-On
On
Off
On
Off
Off
On
profile 38
5BN01-5.04.05 CH1: Clamp-On
Off
On
On
Off
Off
On
profile 39
5BN02-5.04.05 CH1: Clamp-On CH2: Clamp-On
On
On
On
Off
Off
On
profile 40
5DVN02-5.04.05 Dual Path: Clamp-On
Off
Off
Off
On
Off
On
profile 41
5DVN03-5.04.05 Dual Path: Clamp-On
On
Off
Off
On
Off
On
profile 42
5DVN04-5.04.05 Quad Path: Clamp-On
Off
On
Off
On
Off
On
profile 43
5GN03-5.04.05 CH1: Clamp-On

Table of Contents