EasyManua.ls Logo

Siemens SITRANS F US - Profile 15

Siemens SITRANS F US
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix A
A.1 Modbus, EIP, HART & N2 Profile Mappings
F US Clamp-on Communications Protocol Manual
92 Hardware Installation Manual, 11/2015, A5E34981613-AC
Delta Time
Path 2
30181 4 Real Analog_In 24 Float n/a ADF(Float) 19 1
Delta Time Units
30629
8
String
String_In
36
UINT16
n/a
BD(Byte)
73
8
Aux Input 1
30285
4
Real
Analog_In
25
Float
n/a
ADF(Float)
20
1
Aux 1 Type
30813
8
String
String_In
40
UINT16
n/a
BD(Byte)
81
8
Aux Input 2
30287
4
Real
Analog_In
26
Float
n/a
ADF(Float)
21
1
Aux 2 Type
30817
8
String
String_In
44
UINT16
n/a
BD(Byte)
89
8
Aux Input 3
30289
4
Real
Analog_In
27
Float
n/a
ADF(Float)
22
1
Aux 3 Type
30821
8
String
String_In
48
UINT16
n/a
BD(Byte)
97
8
Aux Input 4
30291
4
Real
Analog_In
28
Float
n/a
ADF(Float)
23
1
Aux 4 Type
30825
8
String
String_In
52
UINT16
n/a
BD(Byte)
105
8
A.1.16
Profile 15
Profile 15 (FUS1010-5N04-5.04.05-1+2CO)
Data Description
Modbus
Ethernet/IP
HART
N2
Reg
Bytes
Type
Tag Name
OS
Format
CMD
VAR
Type
Ad
Sz
Site ID
30501
8
String
String_In
0
UINT16
n/a
BD(Byte)
1
8
Date: Year
30101
2
Integer
Analog_In
0
Float
n/a
ADI(Int)
1
1
Date: Month
30102
2
Integer
Analog_In
1
Float
n/a
ADI(Int)
2
1
Date: Day 30103 2 Integer Analog_In 2 Float n/a ADI(Int) 3 1
Time: Hour
30104
2
Integer
Analog_In
3
Float
n/a
ADI(Int)
4
1
Time: Minute
30105
2
Integer
Analog_In
4
Float
n/a
ADI(Int)
5
1
Time: Second
30106
2
Integer
Analog_In
5
Float
n/a
ADI(Int)
6
1
C1 Inst.Flow
Rate
30109 4 Real Analog_In 6 Float 129 6-06h T ADF(Float) 1 1
C1 Flow Rate
Units
30517 8 String String_In 4 UINT16 131 6-06h BD(Byte) 9 8
C2 Inst.Flow
Rate
30111 4 Real Analog_In 7 Float 129 7-07h Q ADF(Float) 2 1
C2 Flow Rate
Units
30521 8 String String_In 8 UINT16 131 7-07h BD(Byte) 17 8
C3 Inst.Flow
Rate
30113 4 Real Analog_In 8 Float 129 8-08h ADF(Float) 3 1
C3 Avg Flow
Rate
30125 4 Real Analog_In 9 Float 129 3-03h P ADF(Float) 4 1
C3 Flow Rate
Units
30525 8 String String_In 12 UINT16 131 3-03h BD(Byte) 25 8
C1 Total 30145 4 Real Analog_In 10 Float 129 34-22h ADF(Float) 5 1
C1 Total Units
30557
8
String
String_In
16
UINT16
131
34-22h
BD(Byte)
33
8
C2 Total
30147
4
Real
Analog_In
11
Float
129
35-23h
ADF(Float)
6
1
C2 Total Units
30561
8
String
String_In
20
UINT16
131
35-23h
BD(Byte)
41
8
C3 Total 30149 4 Real Analog_In 12 Float 129 36-24h
S
ADF(Float) 7 1
C3 Total Units
30565
8
String
String_In
24
UINT16
131
36-24h
BD(Byte)
49
8
C1 Sonic Vel
30157
4
Real
Analog_In
13
Float
n/a
ADF(Float)
8
1
C2 Sonic Vel
30159
4
Real
Analog_In
14
Float
n/a
ADF(Float)
9
1

Table of Contents