Appendix A
A.1 Modbus, EIP, HART & N2 Profile Mappings
F US Clamp-on Communications Protocol Manual
Hardware Installation Manual, 11/2015, A5E34981613-AC
137
C1 Delta Time
30179
4
Real
Analog_In
19
Float
n/a
ADF(Float)
14
1
C1 Delta Time
Units
30629 8 String String_In 48 UINT16 n/a BD(Byte) 97 8
C1 Analog
Input 1
30277 4 Real Analog_In 20 Float n/a ADF(Float) 15 1
C1 AI1 Units
30797
8
String
String_In
52
UINT16
n/a
BD(Byte)
105
8
C1 Chiller
Efficiency 1
30213 4 Real Analog_In 21 Float n/a ADF(Float) 16 1
C1 Chiller
Efficiency 2
30219 4 Real Analog_In 22 Float n/a ADF(Float) 17 1
C1 Chiller
Efficiency 3
30225 4 Real Analog_In 23 Float n/a ADF(Float) 18 1
C1 CE Units 30669 8 String String_In 56 UINT16 n/a BD(Byte) 113 8
C2 Site ID
30505
8
String
String_In
60
UINT16
n/a
BD(Byte)
121
8
C2 Avg Energy
Rate
30203 4 Real Analog_In 24 Float 129 41-29h Q ADF(Float) 19 1
C2 Inst.Energy
Rate
30197 4 Real Analog_In 25 Float n/a ADF(Float) 20 1
C2 Energy Rate
Units
30657 8 String String_In 64 UINT16 131 41-29h BD(Byte) 129 8
C2 Energy Total
30209
4
Real
Analog_In
26
Float
129
44-2Ch
ADF(Float)
21
1
C2 EnergyTotal
Units
30665 8 String String_In 68 UINT16 131 44-2Ch BD(Byte) 137 8
C2 Inst.Flow
Rate
30111 4 Real Analog_In 27 Float 129 7-07h ADF(Float) 22 1
C2 Avg Flow
Rate
30123 4 Real Analog_In 28 Float 129 2-02h T ADF(Float) 23 1
C2 Flow Rate
Units
30521 8 String String_In 72 UINT16 131 2-02h BD(Byte) 145 8
C2 Raw Flow
30135
4
Real
Analog_In
29
Float
n/a
ADF(Float)
24
1
C2 Raw Flow
Units
30541 8 String String_In 76 UINT16 n/a BD(Byte) 153 8
C2 Total
30147
4
Real
Analog_In
30
Float
129
35-23h
ADF(Float)
25
1
C2 Total Units 30561 8 String String_In 80 UINT16 131 35-23h BD(Byte) 161 8
C2 Sonic Vel
30159
4
Real
Analog_In
31
Float
n/a
ADF(Float)
26
1
C2 Sonic Vel
Units
30581 8 String String_In 84 UINT16 n/a BD(Byte) 169 8
C2 Supply Temp
30305
4
Real
Analog_In
32
Float
n/a
ADF(Float)
27
1
C2 Supply Temp
Units
30777 8 String String_In 88 UINT16 n/a BD(Byte) 177 8
C2 Return Temp
30311
4
Real
Analog_In
33
Float
n/a
ADF(Float)
28
1
C2 Return Temp
Units
30785 8 String String_In 92 UINT16 n/a BD(Byte) 185 8
C2 Temp
Difference
30317 4 Real Analog_In 34 Float n/a ADF(Float) 29 1
C2 Temp Diff
Units
30793 8 String String_In 96 UINT16 n/a BD(Byte) 193 8
C2 Signal
Strength
30168 2 Integer Analog_In 35 Float n/a ADF(Float) 30 1